Parameter
| ITEM |
UNIT |
DATA |
Injection Unit |
Screw Diameter |
mm |
40 |
45 |
48 |
| Screw L/D Ratio |
L/D |
22.5 |
20 |
18.8 |
| Injection Volume |
cm3 |
251 |
318 |
362 |
| Shot Weight |
g |
229 |
289 |
329 |
| Plasticizing Capacity |
g/s |
16 |
18 |
20 |
| Injection Rate |
g/s |
116 |
147 |
167 |
| Injection Pressure |
Mpa |
202 |
159 |
140 |
Clamping Unit |
Clamping Force |
KN |
1680 |
| Opening Stroke |
mm |
420 |
| Mould Thickness(Min-Max) |
mm |
180-500 |
| Space Between Tie-Bars |
mm |
455×455 |
| Hydraulic Ejection |
KN |
45 |
| Ejector Stroke |
mm |
140 |
| General |
Motor Power |
KW |
15 |
| Heater |
KW |
10 |
| Pump Pressure |
Mpa |
16 |
| Machine Dimension |
m |
5.2×1.4×2 |
| Machine Weight |
T |
4.8 |
| Mould Orientation Ring Diameter |
mm |
125 |
| Nozzle Radius |
mm |
SR15 |

(Click the two pictures above and blow up them)
Standard Device
- Double-cylinder balance injection system
- Multi-stage pressure & speed injection
- Back-pressure adjustment device
- Decompression
- High speed clamping
- Low pressure mold protection
- Multiple hydraulic ejector knock-out
- Lubrication system
- Hydraulic pressure full proportional control
- All computer control system
- Molding data memory sytem
Standard Accessories
- Mechanical leveling pad
- Spare parts
- Lubrication oil
Selectable
- Drying hopper
- Auto-loader
- Hopper magnet
- Mold clamps
- Hydraulic unscrew device
- Water cooler
- Mold temperature controller
- Auto color mixer with measuring device
- Oil temperature controller
- Oil bypass filter
IIIuminations
Theoretics shot capacity=(plastic injector feeder section area)×(screw stroke) Shot weight is 91% PS theoretics shot capacity Plasticizing ability and shot speed are PS value
Notes: The machine pictures are for your visual reference, may have trivial difference from the actual machines.
|